[Audio] NOCN Level 3 Award in Energy Efficiency Measures for Older and Traditional Buildings UNIT 3 Evaluating the option for introducing energy efficiency measures to older and traditional buildings BS 7913.

Scene 2 (20s)

Justify the selection of energy efficiency measures Legislation and guidance drivers are a common cause of unsympathetic and unrealistic expectations regarding a building along with the use of inappropriate materials to achieve building standards. This can be seen in the application of the following measures: • Wall Insulation that does not consider damp issues • Installation of injected damp proof courses • Replacement of timber floors with insulated concrete • Replacement of windows with double glazed units • Installation of loft insulation • Installation of mechanical ventilation systems.

Scene 3 (43s)

Justify the selection of energy efficiency measures.

Scene 4 (1m 9s)

JUSTIFIED Justify the selection of energy efficiency measures • Rationale for why energy efficiency measures may, or may not, have been selected. • The choice of energy efficiency measures is likely to be governed by what are the priorities, although another critical factor will be affordability. • Improvements...will often depend on factors such as whether improvement work can be carried out...without damaging existing fabric . or whether potential solutions are compatible with the existing construction'. • In all cases the 'do nothing' approach should o b considere •nitiall.

Scene 5 (1m 32s)

• Justify the selection of energy efficiency measures • Specific design, installation or operational features used to minimize the impact of the chosen energy efficiency measure must be considered! MOTIVATION.

Scene 6 (1m 42s)

Delivery of the Energy Efficiency Measures. Planning the work of installing energy efficiency measures must always be done in consultation with the householder/occupants..

Scene 7 (2m 13s)

The Roles and Responsibilities in a Retrofit Project The range of roles include; Retrofit Assessor/Domestic Energy Assessor Retrofit Coordinator Designer Installer/subcontractors The professional team will require qualifications, skills, knowledge The installers will require Vocational competence.

Scene 8 (2m 27s)

The Stages of a Retrofit Project Design Installation Testing Commissioning Handover and handover advice to occupants Ongoing monitoring and fine-tuning, such as post occupancy evaluation Evaluation (including auditing against proposed works) Future maintenance of the building and energy efficiency measures.

Scene 9 (2m 49s)

Retrofitting Traditional Buildings for Energy Efficiency.

Scene 10 (2m 59s)

K?T7QDFJT.