5 TOWERS 2 PONT TOWERS 3 BAR TOWERS FAR 1343 at 180.00m (NBCOasod BHL)' FAR 16.14at 198.60m (NBCOased GFAY> FAR 16.10 at 223.40m cocoased GFAY 223 68 ResiFloors COC.based GFA) 198 60m 60 ResiF100rs CNBC-based GFA) 180 oom 54 ResiFloors (NBC-based BHL) .TOWERI 23 68 FLOORS cac) OORS(BHLY•, 20 FL 10 FLOORS.
5 TOWERS 2 POINT TOWERS. 3 BAR TOWER FAR 13.43 at 180.00m (NBC-based BHL)' FAR 16.14at 198.60m (NBC-based GFAP FAR 16.10 at 223.40m (OC-based GFA)€a PODIUM TOWERI TOWER 2 TOWER 3 TOWER 4 TOWER S OFFICE TOWER ot w. set 2 floors floors (NBC-based BHL) 60 fbcrs (NBC-based GFA) 6B floors (QC-bzed GFA) 54 floors (NBC-beed BHL) 60 floors (NBC-based GFA) 68 floors (GCOsed GFA) floors (NBC-based BHL) 60 flozrs (NBC-based 68 floors (GCOsed GFA) 20 to flÄrs 20 floats 3 0 EPIFANIO 4 OFFIC say AVENUE o 10 LOS SANTO 5.
[Audio] POLLUTION. POLLUTION.
[Audio] POLLUTION POTENTIAL IMPACT: DURING CONSTRUCTION PHASE AIR Dust during construction Emission of vehicles and equipment NOISE Increase of noise level measurement due to equipment and vehicle movement. WATER Uncontrolled surface run off Improper disposal of domestic waste water LAND Aesthetics and Siltation Generation of solid wastes, Hazardous Wastes. Removal of existing vegetation PEOPLE Health and Safety due to exposure to Construction Hazards.
[Audio] POLLUTION AIR Perimeter closure of the area Protection and maintaining existing trees in the area Usage of existing paint technology that can contribute in pollution control. Regular Preventive Maintenance to all equipment and vehicles Sprinkling of water using water tanker daily especially during dry season. Cover all trucks using tarpaulin during hauling period.
[Audio] NOISE Provision for buffer zone and perimeter fence. Regular Preventive Maintenance to all equipment and vehicles STRICTLY observe construction working hours at 7:00am to 7:00pm Construction Equipment should be placed (at least 50 meter) away from the residential area and will see to it that the noise level measurement within the neighboring villages is at standard 65 dBA..
[Audio] WATER Provision of tire bath at the entry and exit point of the property Proper canal drainage ditch to divert waterflow Proper management of stockpile On-site portable toilets and washrooms and the collection of domestic waste will be done by a DENR accredited hazardous waste hauler and treater. Provision of rain water harvesting system. Retain permeable area within the property for proper water absorption..
[Audio] LAND Establishment of boundaries with proper and appropriate fence to the adjacent properties. Water spraying of open areas and access roads Protection and maintain existing trees as possible. Proper disposal and segregation of construction solid and hazardous waste..
[Audio] PEOPLE Implement the wearing of PPE's at all times when inside the project site Installation of signages showing information on the development area, equipment navigation and safety precautionary measures. Proper lighting in and around the project site.
[Audio] AIR CO and NOx due to emission of gensets WATER Generation of untreated/improper disposal of domestic wastewater. Uncontrolled surface run-off Flooding LAND Increase in volume of traffic Improper dumping of solid wastes and toxic substances.
[Audio] AIR Genset would be placed in a separate and closed area Genset will be provided with filter. Regular Maintenance and Testing of Genset.
[Audio] WATER Maintain properly the Rainwater Collection and Harvesting system. Maintain permeable area within the property. Regular monitoring and maintenance of catch basins and manholes. Provision of government compliant and operational STP. Regular monitoring of efficiency of the STP.
[Audio] LAND Implementation of Traffic Management Plan Assigning a dedicated personnel to manage the traffic flow. Strict compliance to proper disposal of solid wastes, hazardous waste. Proper segregation of waste..
[Audio] TRAFFIC. TRAFFIC.
[Audio] TRAFFIC POTENTIAL TRAFFIC IMPACT: Increased traffic flow of the EDSA – T. Benitez and adjacent areas Lack of parking spaces Possible informal terminals of taxis and TNVS Pedestrian Facilities.
[Audio] TRAFFIC SOLUTIONS AND MITIGATIONS: The access to the project site would be situated along EDSA in coordination with the local government and concerned agencies. Implementation of appropriate traffic management system such as proper assignment and signages of ingress and egress. Assigning a dedicated personnel to direct traffic and the flow especially when vehicles are coming and moving out of the project site. All traffic system would be coordinated with the LGU and be based on the recommendation of the Traffic Impact Assessment (TIA) Strictly no street parking along T. Benitez Street No loading and Unloading or Bus stop station Provision for an overpass.
[Audio] Drop-off would be inside the property One- way scheme flow circulation inside the property. Provision of adequate Parking Spaces based on the National Building Code. Parking Slots: Min. number required = 1,339 parking slots (based on NBC) Project Provision = 2,965 slots and 180 slots for Commercial.
[Audio] FLOODING. FLOODING.
[Audio] RISK OF FLOODING: The risk of flooding is already present in the area as per experience of the residents and local government. However, there are concerns from the neighboring villages of the project site about the: Possibility of increased flooding due to the development. Discharge storm water or waste water to the Aranan Creek. Surface run-off due to lack of permeable land..
[Audio] Drainage System: The Proposed Storm Water and STP drainage system is to be tapped on existing provisions along EDSA and no discharge would be made on the Aranan Creek.