[Audio] Bio Gene BIOTECHNOLOGIES INC. . . Bio Gene.
[Audio] ISO 9001: 2000 certified company engaged in manufacturing & exporting of Bio Gene brand of wide range of Thermo setting equipment for laboratories, Industries, universities & research institutes. The equipment range offered by us are in conformance with CE, GMP and EU standards. Bio Gene equipment finds wide application for conducting various quality Control, Production, researches and experiments worldwide. Bio Gene follow stringent quality management system in all our business activities, through qualified team of proficient quality analysts. They make sure to follow quality measures at every production stage right from procurement of raw material to final dispatch of the range. Further, the product assortment is quality inspected at all stages of production under the able guidance of our quality team. Presently, apart from the domestic markets, Bio Gene serves the demands of clients based in USA. Biotechnologies Inc Biotechnologies Inc. European quality award winner, manufacturers of laboratory equipment, scientific equipment and research equipment is a leading exporter of laboratory equipment, scientific equipment and laboratory equipment around the globe. Bio Gene lab equipment, scientific equipment and laboratory equipment have credited with CE..
. . . AWARDS & HONORS. . . . . . . . . .
[Audio] BIOTECHNOLOGIES INC® Winner of European Quality Award) ISO 9001 2015 12835 13/JULY/2019 ISO 13485 2016 1395 13/JULY/2019 ISO 14644:2015 9486350 3/APRIL/2021 CE EN- 12469 EN- 610101 EN- 61010 9480 27-DEC-2019 CE ( MDD) ( 93/42/ EEC) 9453 13/JULY/2019 US- FDA 199251 26/FEB/ 2021 ANSI 49-2019 10252023 22/AUG / 2020 WHO GMP 1024103 15-DEC-2020) GMP 60601 02/AUG/ 2019 RoHS 22489 02/AUG/ 2019 OHSAS 18001 : 2007 1801242 06/AUG/ 2019 ACCREDITED FROM UCS (unitas certification services UK) GMS Certification UKCL (UK).
[Audio] Bio Gene Table Top Autoclave Model No.: BTI-VA- 22.
[Audio] APPLICATION Bio Gene Table Top Autoclave are manufacturer to comply to European class B standard, this sterilizer also pass the BOWIE and DISK Test and lelix tests for detection of steam & penetration as well. Bio Gene Table Top Autoclave have function for three step pre vacuum drying and depth of pre vacuum with 0.85 bar pressure. The residual humidity is well below < 0.2. There improved design with B class porocity and hollow tube ensures removal of internal air even at hollow instruments, the steam at high temperature is evenly distributed all over the chamber. Bio Gene unique design of this high tech sterilizer also ensure 100% sterilization of cotton as well apart from the instruments used. The sterilizers are capable to give data output through USB port or can be coupled to a mini printer. The microprocessor based software is easy and operator friendly and menu driven to give ease in operations..
[Audio] FEATURE Steam generator and boiler heating separated. We adopt the Steam generator to produce steam, which is mounted separately with controlled steam indent, so that we can manipulate the speed and volume of steam generated, reducing the water consumption, and also improved the lifetime of heating circle because of the lower temperature of boiler. The material of Lid safe & reliable Imported 2mm SU304 stainless steel Lid is used to ensure safety when the inside chamber have a higher pressure and also this will avoid the second times pollution which caused by the corrosion from the Lid. Advantages of the control system Our Sterilizers are a result of Research & Development for unique temperature and pressure control technology to ensure the Positive and negative temperature of every two points inside chamber which is less than 0.5℃, guarantee complete sterilization。 The reliability of measurement accuracy The measurement accuracy of temperature: 0.1 ℃,The measurement accuracy of pressure: 0.001 bar。.
[Audio] Bio Gene Autoclave sterilizer is supplied with the Sterilizer chamber capacity in 18 LITER (usable volume ). Bio Gene Table top Top loading autoclave sterilizer is provided with the installed facility of B-process Type of cycle processes. Bio Gene Tabletop Autoclave Top Loading Sterilizer is supplied with Chamber not pre -heating facility which is equipped with an electrically heated jacket for preheating on stand by mode. Hinged Door is inbuilt in Bio-Gene Table Top Sterilizer Chamber. Sterilizer Chamber door Operation: Manual. Sterilizer Chamber Type: Rectangular Bio Gene Tabletop Autoclave Top Loading Sterilizer is supplied with Chamber not pre-heating facility which is equipped with an electrically heated jacket for preheating on stand by mode. Hinged Door is inbuilt in Bio-Gene Table Top Sterilizer Chamber. Sterilizer Chamber door Operation: Manual. Sterilizing Cycle Processes available: 121 degree C Wrapped,.
[Audio] Bio Gene Table Top Autoclave Sterilizer has No water circulation system so that no drain point and fixed water inlets. Bio Gene Table Top Autoclave Sterilizer is supplied without steam generator designed for integrated energy storing system for no building up power for sterilization load in shot time. Number of Trays in sterilizer chamber is 1. Sterilizer Loading Type: Top loading Audio- visual Alarm facility available for Temperature sensor failure, Pressure sensor failure, Phase time out, Door improperly closed, Power failure (no alarm if duration of power failure < 10 sec), Safety device malfunctioning, Low water level. Consumables: Bio Gene Sterilizer unit supplied with installed capability of consumables sufficient to carry out sterilization cycles (No): sufficient for 50 sterilization cycles. Compliance of Chamber for Chamber Pressure Equipment Directives ( PED) AND EN 13445 norms:No Bio Gene Table Top Autoclave Sterilizer is supplied having the warranty period of 1 years. Accessories: Each Tabletop autoclave unit is supplied along with: One Rack unit with 5 levels and one set of suitable sized instrument trays. Compliance of Chamber for Chamber Pressure Equipment Directives (PED) AND EN 13445 norms:No.
[Audio] Capacity 18 Liter sterilizing temperature 121 degree C Wrapped, Type of cycle processes available B- process Sterilizer Chamber Type Rectangular Display LCD Chamber pre-heating facility: Equipped with electrically heated jacket for preheating on standby mode: No Type of Sterilizer Hinged door Model Voltage ( V/Hz) Power ( W) Capcity (L) Chamber Capacity (mm) Weight ( KG) BTI- VA- 22 220/50Hz 1800 18 250X355 47.
[Audio] Sterilizer Chamber door Operation: Manual Sterilizer Chamber door Operation: 121 degree C Wrapped, power 18L: 1800W, 23L: 2100W instrument containers 1 trays Sterilizer Loading Type: Top loading Warranty 1 Year Consumables: Sterilizer unit to be supplied with consumables sufficient to carry out sterilization cycles (No) sufficient for 50 sterilization cycles, Quality Compliance available for quality systems as per as per ISO 9001: 2000 , EN ISO 13485: 2003, ISO Yes.